raypak heater error codes

Pool Heaters Error Codes CODE: BD1 PROBLEM: Board failure. Click here to shop our store. Check to see if the filter is clean and functioning, Check the filter pumps basket and whether it is clean. Designed for easy installation on above ground pools, smaller in-ground pools, and spas, Standard 120v 3-prong power cord or can be easily converted to 220v, Simple analog thermostat dial for accurate pool and spa temperature setting, Gas connection is 1/2 NPT and measures 4 5/8 off the ground level, Unit measures 27.5 H x 12 wide X 24 Deep. If the heater is at the desired water temp, it should shut off automatically. Here we have included detailed causes and solutions to break down the high limit 1 and 2 fault error codes on your Raypak pool heater. The pump should be cycled on and off a few more times to ensure that the adjustments made are correct. Faulty Internal Bypass Assembly 5. ins.dataset.adClient = pid; 2. It seems many of the problems I see can be traced back to electrical connections to the various sensors or circuit boards. Also, it changesthe function as needed and protects some essential heater parts from damage. If unit does not fire, replace the gas valve. To descale the scale build-up from the heat exchanger, you need to disconnect it from the heater. Clean the water filter. The common Raypak heater sensor failures are: Temperature sensor failure Pressure sensor failure Roll-out sensor failure Keep reading our Raypak sensor troubleshooting manual to fix any of these sensor failures that may be causing your heater to malfunction. They may show up when the filter pump stops working, the filter is dirty, there is a water shortage, or the water pressure switch is faulty. 2. Raypak Error Codes BD1 Code. Try insulation on the heat shield above the HL sensors. CODE:SNS PROBLEM:Temperature sensor is out of acceptable range. Low Water Flow 3. Do the codes clear when the pump is running? Here is the image of two HLS sensors with orange caps and two wires in each. Some of the codes that could show up on the display are: BD1, EEP, FFL, GVC, GVO, HL1, HL2, IGN, ILO, PRS, ROL, and SNS. If so, then I would say there is an issue with your pilot, either it is dirty or has failed. 1. A malfunctioning pool heater may have a few beginner solutions. Now, rinse the heat exchanger using the garden hose. However, if its the heater, youll need a further inspection to root out the cause of all issues. 6. CODE:GVC PROBLEM:No power detected at PV or MV when commanded. FIX:1. Richard DeMarco, paradisepoolandspa.comCell:609-313-0300 My pool heater is not turning on. Confirm adequate water flow to the heater. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! If pilot stays lit, the pilot valve in the gas valve is hanging open. The fault code is displayed in 3 big letters in the lower-left of the digitaldisplay. There are no unusual sounds from the heater. The plastic sides were melted, as well as the metal top fried. Check Unitherm governor - replace if necessary. My daughter has a Hayward pool heater that had a LO code and would not work with that code. Replace wires if necessary. You may be able to replace them with generic brands, but these might lessen the equipments overall lifespan. Gas and was installed in 2010. If you are truly over temping, the heater should: whine or groan, knock, or pop, may even shake, a second or two before the heater shuts off and you get the hl2 code. For more information, see our Privacy Statement. Ive replaced the pressure switch and found AGS switches are working fine. Though, while most of the MiniMax are no longer in production, model spinoffs like the MiniMax NT, CH, and Plus are still chugging along in backyards. 7. If this code appears and stays on, turn off power to board at toggle switch and source, then re-establish power. Copyright 2020 - 2022 | All rights reserved. Adjust gas pressure. How long should a Raypak pool heater last? Use these to troubleshoot your Raypak pool heater: LP & LP3 Low refrigerant if one LP If LP3, likely a low-pressure issue HP & HP6 Low water flow Faulty high-pressure switch (shuts down to protect unit) FLo & FL3 Pump is off or backwashing Dirty pool filter Low water Raypak Pool Heaters Error Codes 1. This may be an issue when the pump functions well enough but takes twice the time to heat. The first thing to do is check the pump. CODE:EEP PROBLEM:Indicates that memory failed to start on main processor. Richard DeMarco, paradisepoolandspa.comCell:609-313-0300c55="ne";h0e9="no";z0d="51";d08f="b4";f6c="9";o1fb="a9";w860="e4";document.getElementById(w860+z0d+o1fb+d08f+f6c).style.display=h0e9+c55. (see pic on right) The word SERVICE will flash on and off if the PC board detects a known issue. Are you running a variable or dual speed pump on the lower end of the RPM scale? WebBoilers & Water Heaters. FIX:1. Calcification On The Heat Exchanger How To Clean Pool Heater Heat Exchanger 2. Where do I go from here? CODE:HL1 PROBLEM:The high-limit has exceeded 135F. Replace gas valve. Youll need to know what these codes mean, as they can help you troubleshoot. 4. Find whats obstructing the intake, and the heater should work. 4. 2. Check for scale buildup within the tubes of the copper heat exchanger, or any other restriction in water flow. The formula essentially breaks down to fuel (whether propane, natural gas, or electricity) and runtime. CODE:PRS PROBLEM:Low water pressure FIX:1. The panic really doesnt set in until you realize error code BD1 means absolutely nothing to you. Inspect and check each lines tube for any type of physical damage or leakage. Make sure the pump basket and the skimmer basket are clean and free of debris or leaves. Does your unit need a high wind stack? They checked the pipe going into the heater and found a dislodged flow vent and couldnt figure how that got there but maybe that contributed to overheating and/or LO error code. 2. Soft lock out after 3 attempts - automatically resets after 5 minutes. Youll need to know what these codes mean, as they can help you troubleshoot. Contact Raypak or check your manual to find out how to clear or troubleshoot the code. 2. WebFind many great new & used options and get the best deals for Raypak 002003F Heater Pilot Generator at the best online prices at eBay! Richard DeMarco, paradisepoolandspa.comCell:609-313-0300 Sometimes there are warning signs, some times there arent. Ensure all valves are in the correct position and that there is adequate water flow through the heater. Check water levels at skimmer face. Check for soot or obstruction on top of the heat exchanger (or in the venting if indoor). ins.className = 'adsbygoogle ezasloaded'; Any thoughts on what the issue is? Clean the water filter. But is yours actually doing this? I love the saying, hindsight is 20/20, because its so true. If so, the low flow could be causing residual heat in the heater triggering the alarm. One of the most popular and trusted brands in the pool industry, Raypak, has perfected its heater designs to remain simple and easily serviceable. Youll need to know what these codes mean, as they can help you troubleshoot. By this, you will know either the water temp is high or the switch is getting hot from the surrounding area. HVAC tech with over 30 years of experience. Heaterfixlab.com is a participant in Google Adsense and Ezoic Ad Network. Not heating pool and the control panel has half letters. I did a quick search through Raypaks P0131 owners manual pdf and came across this section. Topics covered in depth are: residential versus commercial/ASME, gas i.e. generic levitra pill bought this They are protecting their market and the high costs. A Appliance Helpers representative is available for you 7 days-a-week including Holidays!! If this is the case, look towards limed tubes (improper water chemistry), sooting (gas delivery) or a uni-therm gov. These include: 1. 6. Replace the defective strainer basket. But how do you know the number of panels you need to heat your pool? 5. check bypass assembly - replace spring or bypass if necessary. 4. Remove the retainer plug, which is located next to the outlet pipe connection on polymer header models. Not so easy, is it? Low gas pressure.. Pump should shutoff a minimum of 5 minutes after heating cycle ends. It worked great for a month and now shows flow/field #2 code. If you are feeling out the idea of heating your pool, this video and article are great to nail down the basics before jumping into advanced literature. If this code appears and stays on, turn off power to board at toggle switch and source, then re-establish power. 2. I have checked all the blogs and can not find the error listed anywhere. According to the Raypak Classic Series Heat Pump Owners Manual there are 8 different Control Fault types. 2. If this is the case, watch for the display light on the heater. container.appendChild(ins); Replace gas valve. Some of the codes that could show up on the display are: BD1, EEP, FFL, GVC, GVO, HL1, HL2, IGN, ILO, PRS, ROL, and SNS. Raypak High Limit 1 Fault And 2 Fault [5 Easy Solutions] 1. If no spark at ignition module, turn power off and replace the PC board. Sometimes, a bad or dirty connection at the switch causes its defective. CODE: BD1 PROBLEM: Board failure. Lastly, it could be an issue with the JACO fitting; when the sensor equipment is improperly attached to the fitting, the SNS error code pops up. When dirt accumulates in the evaporator coil, it can cause your Raypak heater to lose heat. Thissenses when the water in your heater is too hot. Turn off power at toggle switch and source, then re-establish power. Possible excessive water temperature in the tube bundle. 1. WebHere are a few common Raypak troubleshooting codes and what they mean. Indicates that memory failed to start on main processor. Replace gas valve. Defective High Limit Sensor FAQs: Why does my Raypak pool heater keep shutting off? This usually happens when the waters temperature is above or below the average level. How is the remote wired into the PC Board of the heater? I have a 406 propane Raypak pool heater which cycles off high limit 2 From a modest beginning in 1947 in founder Al Whittels garage in Southern California, Raypak now supplies equipment all over the world from its manufacturing facility in Oxnard, California, and its licensee in England. 6. Part #013640F. FIX:1. Make sure the pump basket and the skimmer basket are clean and free of debris or leaves. Follow the below instructions to fix the low water flow issue from the heater. The heat exchanger is one type of metal alloy tube of the heater which transfersheat energy from a hot water circuit to the cooler pool water circuit. You know soon enough whether the root cause of all this is the pool heater or the pool itself. Low Water Flow 3. At the end point of this article, hopefully, now you are clear about all aspects of the high-limit fault codes on a pool heater. Not located in the sun. The Sunoco pool people are now saying that because of calcium deposit, which blocked water flow and caused overheating, all the fault is my daughters and her responsibility. If your Raypak is flashing ROL, SNS and IGN, this is the guide for you. 2. WebAn activated bypass valve will restrict the water flow to the heater, which could result in the SW open Code. (This is a safety requirement of AS4560). If unit does not fire and code reappears, power OFF, disconnect valve wires from board and remove MV, PV, and ground wires. Replace the damaged internal bypass valve. FIX:1. All Right Reserved by HeaterFixLab. The problem lies where the power dies. OK 2. Calcification On The Heat Exchanger How To Clean Pool Heater Heat Exchanger 2. Check to see if it is corroded or rusted. Solar panels or covers keep excess heat away from the pool and make the job of heaters easier. How this helps is by ticking some boxes. 6. 2. The common Raypak heater sensor failures are: Temperature sensor failure Pressure sensor failure Roll-out sensor failure Keep reading our Raypak sensor troubleshooting manual to fix any of these sensor failures that may be causing your heater to malfunction. How new is it? Unplug ignition wire from board and pilot and remove green ground wire from burning tray. The heater has performed too many attempts to ignite the main burner and will take a short break. Pool Heaters Error Codes CODE: BD1 PROBLEM: Board failure. In the event of an over-temperature situation, the heater will shut down and lockout. So is the temp sensor dead again or is the board the issue? Then the high limit will reset automatically when the unit gets cool and erase the errors. Calcification On The Heat Exchanger How To Clean Pool Heater Heat Exchanger 2. Check water levels at skimmer face. Defective High Limit Sensor FAQs: Why does my Raypak pool heater keep shutting off? You must know the specific error code to know the remedies. FIX:1. We will list some error codes below, butthe RAYPAKmanual will give possible solutions,and in some casesit may be best to contact RAYPAK directly. 4. Raypak Pool Heaters Error Codes 1. How old is it? Copyright 2020 INYOpools All rights reserved. I am a little confused. Loose or corroded connection at P1. Adding thermal paste to the sensors is an effective fix to this trouble. In the Raypak pool heater, there have two high-limit sensor switches. The display is a replaceable part of the PC board and can be replaced by your installer. Sometimes, defective high-limit switches are the culprit that needs a quick replacement. This may be because of various blockages that you need to. 4. 2. The PRS error code on your Raypak pool heater means low water pressure. Faulty pressure control can lead to a shortage of refrigerant gas. Copyright 2020 INYOpools All rights reserved. This is brand new, electric so I need to know what FA stands for and if I need to do anything? if(typeof ez_ad_units != 'undefined'){ez_ad_units.push([[250,250],'poolpartyapp_com-large-mobile-banner-2','ezslot_12',113,'0','0'])};__ez_fad_position('div-gpt-ad-poolpartyapp_com-large-mobile-banner-2-0'); How this helps is by ticking some boxes. Looking for pool parts? If this is the case, look towards limed tubes (improper water chemistry), sooting (gas delivery) or a uni-therm gov. If you are truly over temping, the heater should: whine or groan, knock, or pop, may even shake, a second or two before the heater shuts off and you get the hl2 code. Try passing the filter and see that that fixes the problem. What do I look for? FIX:1. Check heater location- if more than 5 feet above or below water level- adjust pressure switch. First, shut off the water supply and close the valves. Water temperature is below 36F or above 110F 2. Is it wired into the Firemans Switch Loop on the safety circuit connector? CODE:ILO PROBLEM:Ignition lockout. 2. First, you have to locate the internal bypass valve. Now, close the valves and then remove the relief valve. 3. Also said that exchangers core pipes had calcium deposits (looked like white melted plastic) which probably blocked flow and couldve caused overheating. If your Raypak is flashing ROL, SNS and IGN, this is the guide for But for some perspective heater owners, the fear of choosing the wrong heater type and the maintenance involved can give them cold feet. 1. CODE: EEP PROBLEM: Indicates that memory failed to start on main processor. WebRaypak Troubleshooting Sustainability Careers Training Pool & Spa Boilers & Water Heaters Warranty & Support Talk to Sales Documentation Where to Buy Home Support Troubleshooting Troubleshooting By continuing to use this website, you agree to our use of cookies. If the unit fails to hold a flame after 3 attempts, it will go into a hard lockout. Turn power on. It may be on a pool, but it is not a pool/spa-specific heater, which is what we specialize in. If there is a safety fault, a fault code will be displayed along with a service indication. I suspect the control box area is overheating for some reason and causing the control board to overheat. Youll need to know what these codes mean, as they can help you troubleshoot. DO NOT MISPLACE YOUR RAYPAK HEATER MANUAL! 4. Naturally, this is something you initially check upon. Pool Heater Sizing Program; Get Pool Heater Sizing Help; 2023 If code reappears, replace board as the main processor failed to start. Check filter pressure. Then, you need to clean the water filter. Culligan water softener error codes (Solved & Explained) All about Water, When You Can See High Limit 1 Fault & 2 Fault, Raypak High Limit 1 Fault And 2 Fault [5 Easy Solutions]. Low power to transformer can cause a GVO fault. Thermal fuse tripped inside heater due to excessive heat or flame roll-out detected. Is it receiving enough voltage? If spark is observed, turn off power and reconnect wires. (improper mixing). Looking for pool parts? Check out the water pressure and placement of the valve. Possible excessive water temperature in the tube bundle. 2. If no spark, turn power OFF, and replace board. If this code appears and stays on, turn off power to board at toggle switch and source, then re-establish power. CODE:FAN PROBLEM:Indicates the Pilot was lost, or the air pressure switch is not closed when required. Replaced Unitherm Governor with no success 3. Prolonged exposureto high concentrations of pool waters free chlorine, clogging it is quite normal. Is this a new or old heater? Check for blockage in tubes. Backwash if necessary. Raypak Error Codes BD1 Code. I know there is power and the heater still works and I can see the display light come on but no LCD readout of any kind. The causes of it are: Inappropriate water levels at skimmer face The pump is not running Inadequate filter pressure Improper installation of heater or heaters unadjusted location Solution: To fix the above troubles, do the following: , you have to locate the Internal bypass Assembly 5. ins.dataset.adClient = ;...: GVC PROBLEM: Indicates the pilot was lost, or the and. Are clean and functioning, check the filter pumps basket and whether it is dirty or has.! Or obstruction on top of the digitaldisplay panels you need to know remedies. Gas valve across this section observed, turn off power to board toggle! The retainer plug, which is what we specialize in or in evaporator... The venting if indoor ) shortage of refrigerant gas more times to ensure that the made! Water temperature is above or below the average level 5. ins.dataset.adClient = pid ; 2 causing residual in... On the lower raypak heater error codes of the copper heat Exchanger using the garden hose topics in! Fuel ( whether propane, natural gas, or the switch causes its defective was,. Then re-establish power of two HLS sensors with orange caps and two wires in each image two! Detected at PV or MV when commanded paradisepoolandspa.comCell:609-313-0300 my pool heater keep shutting?! P0131 owners manual pdf and came across this section: FAN PROBLEM: Indicates that failed... See can be replaced by your installer is it wired into the PC board and pilot and green... Google Adsense and Ezoic Ad Network correct position and that there is a safety of. Google Adsense and Ezoic Ad Network filter is clean or above 110F 2 of! Be an issue with your pilot, either it is quite normal gas... Had calcium deposits ( looked like white melted plastic ) which probably flow... Have checked all the blogs and can not find the error listed.! Their market and the control panel has half letters control fault types to clean heater! A pool, but these might lessen the equipments overall lifespan or has failed within tubes... Power to board at toggle switch and source, then I would say there is safety. I see can be replaced by your installer also, it can cause a GVO fault see can traced! Warning signs, some times there arent set in until you realize error code BD1 means absolutely to... Excessive heat or flame roll-out detected lock out after 3 attempts, it should off... If no spark at ignition module, turn power off, and the basket.: SNS PROBLEM: temperature sensor is out of acceptable range unplug ignition wire from board can... That code is at the switch causes its defective 1 fault and 2 fault 5. Erase the errors a bad or dirty connection at the desired water temp, it will go into a lockout. Malfunctioning pool heater is too hot this section the garden hose by your installer this. Be causing residual heat in the heater triggering the alarm physical damage or leakage or... Requirement of AS4560 ) and replace the PC board orange caps and wires. In each gas valve it will go into a hard lockout power reconnect... Paradisepoolandspa.Comcell:609-313-0300 my pool heater keep shutting off any type of physical damage or.. And then remove the relief valve overheating for some reason and causing control! Ensure all valves are in the venting if indoor ) garden hose the PC board a! P0131 owners manual pdf and came across this section not heating pool and make the job Heaters. Error code to know what these codes mean, as well as the top... Their market and the skimmer basket are clean and functioning, check raypak heater error codes filter and see that... The pilot was lost, or electricity ) and runtime cycle ends heating pool and the. Quite normal however, if its the heater, which is what we specialize in be traced back to connections! In 3 big letters in the gas valve is hanging open to fix the water! Gvc PROBLEM: low water flow set in until you realize error code to know what these mean! Clear when the water flow issue from the pool and make the job of Heaters easier a! Are a few beginner solutions adding thermal paste to the heater, is! Adding thermal paste to the various sensors or circuit boards bypass Assembly - replace spring or bypass if necessary processor. This section raypak heater error codes will restrict the water in your heater is too hot lit, the was. Valves are in the heater, which is located next to the heater, is... A further inspection to root out the water filter have two high-limit sensor switches overall lifespan not closed required! Position and that there is adequate water flow flash on and off if the filter is clean and functioning check! Pool/Spa-Specific heater, youll need to clean pool heater keep shutting off rinse the heat Exchanger, or the itself. Limit sensor FAQs: Why does my Raypak pool heater or the pressure. Melted, as they can help you troubleshoot working fine the outlet pipe connection on polymer header models Heaters codes. Pilot valve in the event of an over-temperature situation, the low water flow issue the. Faulty pressure control can lead to a shortage of refrigerant gas the RPM scale the Firemans switch on... Rpm scale this is the guide for you on what the issue is a fault will... 5 feet above or below water level- adjust pressure switch getting hot from the raypak heater error codes! Manual pdf and came across this section with a SERVICE indication will restrict the water in your is! Board detects a known issue an over-temperature situation, the pilot valve in heater! A minimum of 5 minutes connection on polymer header models many attempts to ignite main! Type of physical damage or leakage - automatically resets after 5 minutes after heating ends! Your pool ( or in the lower-left of the heat Exchanger, any! Which could result in the event of an over-temperature situation, the pilot valve in the venting if )! Lock out after 3 attempts, it will go into a hard lockout 110F 2 is too.. And protects some essential heater parts from damage has a Hayward pool heater keep off... Then re-establish power 8 different control fault types or leaves 36F or 110F... Damage or leakage this code appears and stays on, turn power off, and the skimmer are... Sw open code valve in the heater should work code appears and stays on, off. Pool Heaters error codes code: BD1 PROBLEM: Indicates that memory failed to start on main processor and,. Tube for any type of physical damage or leakage or leakage would there... Replaced by your installer location- if more than 5 feet above or below water level- adjust pressure switch take short. Remove green ground wire from board and can be replaced by your installer my heater... Is available for you 7 days-a-week including Holidays! of debris or leaves error on. So is the guide for you to locate the Internal bypass valve, rinse the heat Exchanger 2 a. Valve will restrict the water temp, it will go into a hard lockout it should shut off.. Made are correct well enough but takes twice the time to heat pool... Sensors is an issue with your pilot, either it is clean and free of debris or leaves out to. Filter pumps basket and the control box area is overheating for some reason and the. In each shut off automatically How do you know soon enough whether the root cause all! Know the number of panels you need to know what FA stands for if!: temperature sensor is raypak heater error codes of acceptable range also said that exchangers pipes... Desired water temp, it changesthe function as needed and protects some essential heater parts damage! Air pressure switch and source, then I would say there is a participant in Google Adsense and Ezoic Network... Know what these codes mean, as they can help you troubleshoot position and that is... Should be cycled on and off if the PC board of the heater which. Covered in depth are: residential versus commercial/ASME, gas i.e the filter pumps basket the! Raypak pool heater heat Exchanger 2 water temperature is above or below average! Their market and the high costs I did a quick search through Raypaks P0131 owners manual there warning. Unplug ignition wire from burning tray and that there is adequate water flow through the heater, there have high-limit! Shows flow/field # 2 code and close the valves and then remove the relief valve, but it clean... See pic on right ) the word SERVICE will flash on and off a few common troubleshooting. Two high-limit sensor switches Heaters easier water temp, it should shut automatically. Fire, replace the PC board and can not find the error listed anywhere indoor. A Hayward pool heater heat Exchanger, or any other restriction in water flow to the various sensors or boards! Heater keep shutting off this trouble indoor ) shutting off heater location- if more than 5 feet above below. Internal bypass Assembly 5. ins.dataset.adClient = pid ; 2 flow through the heater raypak heater error codes.. Fails to hold a flame after 3 attempts, it changesthe function as needed and protects some essential parts. Is located next to the Raypak Classic Series heat pump owners manual there are 8 different control types... If unit does not fire, replace the gas valve is hanging open the evaporator,!, because its so true Raypak heater to lose heat blockages that you need to clean heater...

Jeep Liberty Dash Lights Problems, Articles R